Showing results: 16 - 30 of 95 items found.
-
GTX22x0 -
Marvin Test Solutions, Inc.
The GTX22x0 family of PXI universal time interval counters offer many of the measurement and timing functions of high-end stand-alone frequency counters, including accumulate, auto ratio, frequency, fast frequency (GTX2220 and GTX2230 only), period, ratio, single period, test clock, time interval, time interval delay, totalize, totalize gated, totalize gated once, & pulse width.
-
GTX2200 Series -
Marvin Test Solutions, Inc.
The GTX22x0 family of PXI universal time interval counters offer many of the measurement and timing functions of high-end stand-alone frequency counters, including accumulate, auto ratio, frequency, fast frequency (GTX2220 and GTX2230 only), period, ratio, single period, test clock, time interval, time interval delay, totalize, totalize gated, totalize gated once, & pulse width.
-
Crest Test Systems Pvt. Ltd.
Measuring contact timings is useful for finding the contact bounces and non-simultaneity of contacts. This helps in finding the possible electrical or mechanical defects in the circuit breaker contacts. Timing analysis also make it possible to detect incorrect mechanical adjustments and wear phenomena of the circuit breaker by measuring the differences between the fastest and slowest phases.
-
GT668PXI-40 -
Guide Technology, Inc.
A true breakthrough in high-speed Time Measurement and test technology, GuideTech’s GT668PXI-40 leverages the power of its CTIA continuous time-stamping technology, eliminating the need for supplemental triggers, pattern markers or clock recovery circuits.GuideTech’s CTIAs enables serial interfaces pattern verification and full jitter analysis in milliseconds for fast, automated characterization and high-throughput production test on all ATE platforms, including low-cost and in-house testers.GT668PXI-40 cards can be expanded up to 36 Channels Single Ended Input in a single 3U PXI chassis.
-
SR620 -
Stanford Research Systems, Inc.
The SR620 measures time interval, frequency, pulse-width, rise and fall time, period, phase and events. Time intervals are measured with 25 ps rms resolution, making the SR620 one of the highest resolution counters available.
-
Entes Elektronik
ENTES Time Relays are designed to enable control in desired time intervals and have various functions.
-
TMU -
Amida Technology, Inc.
TMU is a dual-channel input and ARM input PCI-based time interval counter (Time Interval Counter) . The internal 40 - bit counter provides a series of precise measurements, including frequency, period, time interval, pulse width, and more. TMU uses a reciprocal counting technique , which enables low-frequency signal measurement, taking into account both measurement accuracy and measurement time. The generator creates and generates many versatile waveforms. The following are the outstanding features of the CT-50 .
-
MRC ltd.
Is a specialized type of clock used for measuring specific time intervals.
-
-
TIC-8420 -
TEAM SOLUTIONS, INC.
The TIC-8420 is a novel Timer/Counter/Analyzer based on digitization of time intervals in pulse trains with 2.8 ns resolution.
-
53230A -
Keysight Technologies
The Keysight 53230A universal frequency counter/timer serves all your frequency and time interval measurement needs. In addition to the typical frequency and time interval measurements, continuous/gap-free measurements are available for basic modulation domain analysis. Optional burst measurement software is available. An optional microwave channel can be added to measure 6 or 15 GHz.
-
HORITA Co., Inc.
Analog composite video and generates standard SMPTE VITC time code and inserts it into the first few lines of active video rather than into the vertical interval where normal VITC is located. This allows the VITC time code to be recorded on various digital video recorders that record the picture content but do not record the actual vertical interval portion of the video signal and in this way allows you to use these digital video recorders to record high quality video and VITC time code.
-
Harmonic Vibration -
ZETLAB Company
The Harmonic vibration program is intended for harmonic oscillations resistance testing within the specified frequency range or at a fixed frequency during the set time interval.
-
ProDAQ 3808 -
Bustec Ltd.
The ProDAQ 3808 function card, an enhanced version of the ProDAQ 3806 counter/timer function card, is designed to operate in one of three modes: pulse counter, frequency meter, or time interval counter. In the pulse counter and frequency measurement modes, users can process incoming signals of up to 25 MHz on each of the six channels. A time interval counter range is divided into six sub-ranges, covering times from 40 ns to 20000 s with a maximum resolution of 10 ns. For pulse-width measurements, the same ranges apply.
-
HRRD730 Series -
HighReach Measuring & Controlling System Co.,Ltd
At The Radar Level gauge Antenna emits and Narrows at The Microwave Pulse. This Pulse propagates in Space AT at The Speed of Light. The When IT Encounters at The Surface of at The the Measured Medium, Part of the ITS Energy IS the REFLECTED the Back and Received by at The Same, Antenna. At The Time interval The Between the transmitted pulse and the received pulse is proportional to the distance from the antenna to the surface of the measured medium.Because the electromagnetic wave propagation speed is extremely high, the time interval between the transmitted pulse and the received pulse is very small (on the order of nanoseconds). It is difficult to confirm. The 90X series 26G radar level gauge uses a special demodulation technology To accurately identify the transmitted pulse and the time interval of the pulse is received to further calculate the distance of the antenna from the surface of the measured medium.